WE HAVE OUR OWN STORAGE
Save to shopping list
Create a new shopping list
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W
nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W

nVent RAYCHEM T2Black-12 R-BK-B-14.5M-180W/T0 floor heating cable 14.5 m / 180 W

Thermostat included
Select variant (heating power / cable length)
85,35 €
incl. VAT / set
Product available
Product available
14 days for easy returns
Safe shopping
Express checkout 1-Click(without registration)

nVent RAYCHEM T2Black-12 heating cable for electric floor heating with a fixed nominal power 12 W/m. It is a factory-terminated two-wire, single-sided, heating cable connected to a 2.6-m-long cold wire.

  • The T2Black-12 kits are available in kits with a digital electronic thermostat NRG-DM and in versions without a thermostat.
  • For easy installation, all T2Black-12 cables are factory terminated and supplied on a spool. They are packaged in a sturdy and handy package containing hot-melt adhesive for easy installation to the substrate, and a protective tube for sensor installation

Recommended installation methods:

  • Under tiles - in a layer of adhesive (the heating cable should be carefully sealed without leaving "air pockets"). - we recommend to lay every 80 mm obtaining 150W/m².
  • Under floor panels, vinyl panels, linoleum, wooden floor - the heating cable should be flooded with self-levelling screed 15 mm - for the mentioned floors lay max. 100 W/m².

Attributes:

  • Safe nominal power of 12 W/m for heat-sensitive floors maintaining a minimum spacing of 120 mm.
  • Very low energy consumption when used together with smart thermostats nVent RAYCHEM compliant Eco-Design standard.
  • No measurable electromagnetic fields due to the use of twisted-pair heating cables
  • Powered from one side, making installation quick and easy.
  • Finally terminated with 2.5 m cold wire.
  • Failure-free and recommended by PRO RAYCHEM installers around the world.
  • Buy even cheaper with a room thermostat.
  • Can be installed in a shower type walk-in.
  • The high quality of the product is confirmed by the warranty which as also covers the repair of the floor to its original condition.

Preparing the substrate

  1. The floor should be clean, stable and rigid, without cracks or substances that reduce adhesion. Large cracks in the substrate should be filled before installation. Uneven surfaces should be leveled before installation.
  2. For cement screed and anhydrite screed, make sure that the screed has dried sufficiently according to the relevant standards. The anhydrite screed should be smoothed, and dust should be removed. For quick-drying mortar, follow the supplier's instructions.
  3. The heating cable should not be installed under bathtubs, shower stalls, standing furniture directly on the floor, etc. The heating cable should not be laid where holes will be drilled in the floor.

Installation instructions

  1. The T2Black-12 cold wire must be routed in flexible conduit and connected in an installation box. The T2Black-12 cable must always be controlled by an electronic thermostat for underfloor heating with an external floor temperature sensor that complies with the Eco-Design Directive (e.g. NRG-DM, GREEN LEAF or SENZ-WIFI).
  2. The floor temperature sensor is also laid in the protective tube (3 m long tube, included in the T2Black kit) and placed centrally, between the two runs of the heating cable, as close as possible to the final floor covering. See instructions.
  3. T2Black-12 can be laid under tile and natural stone. The conduit can even be placed directly into tile adhesive (in which case make sure it is placed in an adhesive layer at least 6 mm thick), or installed directly into counter membranes and/or embedded in leveling mortar or screed.
  4. T2Black-12 can be installed under parquet, laminate or laminate flooring. In this case, it should be embedded in at least a 15-millimeter layer of self-leveling screed, ensuring control by a thermostat with a floor temperature sensor set to a maximum of 27°C. The spacing between the wires should be 120 mm (this will allow to obtain a power of 100 W/m²).

Example of installation under the tiles, in the furrows

In case you care about every millimeter of the floor, the solution may be to install the cable in the dirt. In other cases, we install the heating cables in the adhesive layer under the tiles.

Buy the heating cable even cheaper in a set with a thermostat

floor thermostat

nVent RAYCHEM NRG-DM are intelligent weekly programmable room thermostats designed for electric floor heating systems. They are used to control underfloor heating, providing maximum comfort with the lowest possible energy consumption. It features adaptive function. The NRG-DM thermostat is equipped with an ambient temperature sensor and a floor temperature sensor, so it can control underfloor heating cables in 4 different modes:

  • room temperature measurement,
  • floor temperature measurement or
  • room temperature measurement with floor temperature limitation,
  • as needed.

The entire heating set in a package with an easy roll-out system

Heating cable for the spout

  • All nVent RAYCHEM T2Black-20 floor cables are ready to install
  • Wrapped on a spool with an easy unwind system for easy installation.
  • Packaged in a sturdy and handy installer-friendly box.

Contents of kit:

  • Packaging with easy roll-out system
  • Fabricated heating cable
  • NRG-DM room thermostat (optional)
  • Wired floor temperature measurement sensor
  • Hot glue gun - information
  • Protective tube for floor sensor installation
  • Protective tube cap
  • Installation instructions with acceptance protocol
  • Self-adhesive information label
Symbol
R-BK-B-14.5M-180W/T0
Producer code
5414506021486
Nominal power
12 W/m
Heating cable type
Single-sided powered, fixed-resistance
External insulation
PVC
Mechanical strength
> 600 N (class M1) According to IEC60800 Ed 3.0 2009
Maximum interaction temperature
90°C
Minimum installation temperature
+5°C
Supply voltage
230 V AC
Minimum bending radius
30 mm
Power cord length
2,6 m
Minimum cable spacing
80 mm
Diameter of the heating cable
4.0 mm
Warranty
12 years + thermostat 12 years
Certifications and approvals
CE
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.